{"product_id":"elima-draft-2-way-4-foot-linear-air-deflector-diffuser-cover","title":"Elima-Draft 2-Way 4-Foot Linear Air Deflector \/ Diffuser Cover","description":"\u003cp\u003eThe 2-way linear cover splits the slot discharge to both sides rather than letting it drop straight down the middle. Half one way, half the other.\u003cbr\u003eThat suits the common case where a linear diffuser runs above a walkway, a seating area or a bed and the problem is not which side the air goes, but that it falls directly below. Pushing it sideways in both directions takes the column out of the middle without concentrating it anywhere.\u003cbr\u003eThe cover is 48 inches long, 6 inches wide and 2.75 inches deep, in polystyrene, holding magnetically on the diffuser or a 1-inch grid system. The manufacturer states it suits diffuser widths of roughly 2.75 to 4.75 inches.\u003c\/p\u003e\n\u003ch2\u003eWhat does a 2-way linear deflector do?\u003c\/h2\u003e\n\u003cp\u003eIt opens both sides of the slot and spreads the discharge across them. The air still leaves the diffuser at the same rate, but instead of dropping into the space directly underneath it travels sideways in two directions along the ceiling. Each side carries roughly half, so neither stream throws as hard as the single-side 1-way does. On a 4-foot slot that difference is easy to feel standing underneath.\u003c\/p\u003e\n\u003ch2\u003eWhy choose 2-way over 1-way on a linear run?\u003c\/h2\u003e\n\u003cp\u003eBecause a 4-foot slot pushing everything one way is a lot of air on one line. The 1-way is the right call when one side is genuinely unusable, a window you want to wash with air or a wall you need to keep clear of. The 2-way is the better default when both sides have somewhere for the air to go, since halving the throw makes it gentler in each direction and you are less likely to create a second complaint at the far end of the room.\u003c\/p\u003e\n\u003ch2\u003eWill it fit your diffuser?\u003c\/h2\u003e\n\u003cp\u003eWidth first. The manufacturer states this cover suits diffuser widths of roughly 2.75 inches up to and including 4.75 inches, so measure the slot before ordering. Outside that range it is the wrong part. Then the attachment surface, because the magnets hold on the diffuser or a 1-inch grid and both need to be steel. Then clearance: 2.75 inches below the ceiling line for the depth of the cover. Measure the slot itself rather than the trim around it, since the trim can be an inch wider than the opening and will give you the wrong answer.\u003c\/p\u003e\n\u003ch2\u003eWhat if your run is longer than 4 feet?\u003c\/h2\u003e\n\u003cp\u003eCount the sections before you order. Each cover is 48 inches, so a 12-foot run needs three and an 8-foot run needs two. Where a run does not divide evenly, decide in advance where the uncovered gap sits. The 2-way is more forgiving than the 1-way here. With both sides open the pattern stays symmetrical, so a gap in the middle of a treated run reads less obviously than it would with a one-sided throw, where the untreated section suddenly behaves differently from its neighbours.\u003c\/p\u003e\n\u003ch2\u003eHow does it install?\u003c\/h2\u003e\n\u003cp\u003eLift it to the slot and let the magnets take it. Nothing to screw, wire or make good. Orientation is less critical than on the 1-way since both sides are open, which makes a 4-foot part easier to place single-handed, though a second person still helps. Once it is up, stand underneath and check what has changed before moving on to the next section.\u003c\/p\u003e\n\u003ch2\u003eDoes this affect the rest of the system?\u003c\/h2\u003e\n\u003cp\u003eLittle at a single run. The slot passes the same volume and simply delivers it sideways instead of downward. Across a long perimeter treated section by section, the combined effect is a broader, gentler delivery rather than a redirect, which is generally the easier change for a system to absorb. If you are covering an entire elevation, mention it to whoever looks after the HVAC.\u003c\/p\u003e\n\u003ch2\u003eIs this a filter?\u003c\/h2\u003e\n\u003cp\u003eNo. It changes where the air goes, not what is in it. No filter media, no MERV rating, no filtration claim. Filtration is a separate product line.\u003cbr\u003e\u003c\/p\u003e","brand":"SUPPLYOWL.COM","offers":[{"title":"1-way","offer_id":54287030190373,"sku":"ELI-LINEAR-1-WAY","price":99.99,"currency_code":"USD","in_stock":true},{"title":"2-way","offer_id":54287030223141,"sku":"ELI-LINEAR-2-WAY","price":99.99,"currency_code":"USD","in_stock":true},{"title":"Solid","offer_id":54287030255909,"sku":"ELI-LINEAR-SOLID","price":99.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/8307\/8949\/files\/eli-linear-2-way-air-deflector.jpg?v=1793210041","url":"https:\/\/www.supplyowl.com\/products\/elima-draft-2-way-4-foot-linear-air-deflector-diffuser-cover","provider":"SUPPLYOWL.COM","version":"1.0","type":"link"}